Chocolate PTA Balloon

Chocolate PTA Balloon

TheChocolate PTA Balloon is an “over-the-wire” balloon dilatation catheter with a braided shaft and an atraumatic tapered tip.

Chat Now
Product Introduction


OVERVIEW of Chocolate PTA Balloon

The Nitinol PTA Balloon Catheter is an “over-the-wire” balloon dilatation catheter with a braided shaft and an atraumatic tapered tip.


INTENDED PURPOSE of Chocolate PTA Balloon

Chocolate PTA Balloon positioning global products, we gradually follow up planning to sell to the European Union, users for the peripheral vascular system ( including the iliac artery, femoral artery, iliofemoral artery, iliac artery ) need to perform percutaneous intravascular angioplasty Patients undergoing surgical (PTA) surgery.

4b398347b8880d715cd8be129dc96f9

PRODUCT DETAILS of Chocolate PTA Balloon

Chocolate PTA Balloon (abbreviated as balloon catheter) consists of tip, marking ring, balloon, metal mesh, welded tube, connecting tube, inner tube, braided tube, catheter reinforcement tube and catheter seat. The surface of the balloon catheter is coated with a hydrophilic coating that covers a length of 300 mm ± 50 mm from the distal end of the braided tube to the position of the connector . The balloon catheter has a coaxial structure.


The design of the balloon catheter is coaxial. The balloon is a semi-compliant balloon; the balloon catheter is a non-hydratable catheter, and is made of a medical polymer material that is non-toxic to the human body, does not react with the tissue skin cleanser at the insertion part, and has no particles falling off.


image

PRODUCT FEATUURES 

Braided catheter

Improved pushability, excellent anti-kink performance

Hydrophilic coating reduces frictional force on the catheter shaft


Coaxial tip:

Smaller outer diameter for better passing


Semi-compliant balloon

Helps to match the metal mesh with the best concave and convex structure


Constraint structure of Nitinol metal mesh:

Avoid shearing force on blood vessels during balloon expansion

Realize the uniform distribution to prevent the "dog bone" effect

The balloon has excellent reclamation properties, avoiding the "Pancake" effect

Grooves: relieve pressure and optimize plaque

Protrusion: Controllable expansion of blood vessels, minimizing damage caused by blood vessel expansion


Exhibition

Scoring balloon catheter


CONTACT WAY

Name: Eiffel Lu

Email: LLLU@batymedical.com

Mobile: +86 182 2165 9426 (whatsapp)

Hot Tags: chocolate pta balloon, China, suppliers, manufacturers, factory, customized, OEM

Send Inquiry

whatsapp

skype

E-mail

Inquiry

Bag