0.014" RX PTA Balloon Catheter
The WANTY PTA Balloon Catheters are indicated for peripheral transluminal angioplasty (PTA) for peripheral vascular system (including the iliac artery, femoral artery, iliac femoral artery, popliteal artery and inferior genicular artery).The device is indicated to dilate the stenotic vascular to the calculated diameter for the treatment of obstructive disease of peripheral arteries.
Clinical application
Guide wire fitting system | Site of Lesion |
0.035 system | Iliac artery, superficial femoral artery, proximal popliteal artery, iliofemoral artery, hemodialysis and venous dilation |
0.018 system | Carotid arteries, renal arteries, superficial femoral arteries, infra-knee arteries, stubborn in-stent restenosis |
0.014 system | Inferior knee artery, dorsal foot artery |
Clinical application (Lower extremity)
Product Features of 0.014" RX PTA Balloon Catheter
Angioplasty Balloon Catheter with Rated bursting pressure
-- It can be applied to the expansion of highly calcified lesions
Low compliance balloon
-- The new balloon formation method reduces the occurrence of "dog bone" phenomenon
The reduced thickness of the balloon wall makes it compatible with the 5Fr sheath
PTA Balloon catheter Technical Specification
Compliance | Balloon Size | Balloon Length | Shaft length | Catheter Design | Guidewire Compatility Inch |
SC PTA Balloon | 1.5mm- 5.0mm | 20- 210mmm | 100/130/150cm | coaxial | 0.014 |
SC PTA Balloon | 2.0-9.0mm | 20-220mm | 90/130/180cm | coaxial | 0.018 |
SC PTA Balloon | 2.0-9.0mm | 20-220mm | 90/130/180cm | doulbe lumen | 0.018 |
SC PTA Balloon | 2.0-10.0mm | 20-220mm | 80/130cm | coaxial | 0.035 |
SC PTA Balloon | 2.0-10.0mm | 20-220mm | 80/130cm | doulbe lumen | 0.035 |
NC PTA Balloon | 2.0-5.0mm | 20-220mm | 100/150cm | coaxial | 0.014 |
NC PTA Balloon | 2.0-7.0mm | 20-220mm | 90/130/180cm | coaxial | 0.018 |
NC PTA Balloon | 2.0-7.0mm | 20-220mm | 90/130/180cm | doulbe lumen | 0.018 |
NC PTA Balloon | 2.0-10.0mm | 20-220mm | 40/80/130cm | coaxial | 0.035 |
NC PTA Balloon | 2.0-10.0mm | 20-220mm | 40/80/130cm | doulbe lumen | 0.035 |
More AVF PTA Balloon angioplasty ordering information please contact your sales.
Barty medical Enterprise Operation Principle
Barty Medical shares your commitment to achieving the best possible patient outcomes,
and connecting healthcare professionals with the finest medical technologies and supplies in the market.
Our products range from the consult room to the operating theatre delivering leading technology
into the most capable hands.
By continuing, you are acknowledging that you are a registered healthcare professional with
a valid certification.
We design solutions that support life-saving procedures and satisfy unique application and performance needs, while maintaining tight, repeatable outcomes.
Contact Way
Hot Tags: 0.014" rx pta balloon catheter, China, suppliers, manufacturers, factory, customized, OEM