0.014" RX PTA Balloon Catheter

0.014" RX PTA Balloon Catheter

0.014" RX PTA Balloon Catheter Intended use of Peripheral Balloon Catheter: Medical Peripheral Angiography Catheter used in the patient’s peripheral vascular, and for a variety of diagnostic and therapeutic medical procedures.

Chat Now
Product Introduction

Production Introduction

0.014" RX PTA Balloon Catheter


The WANTY PTA Balloon Catheters are indicated for peripheral transluminal angioplasty (PTA) for peripheral vascular system (including the iliac artery, femoral artery, iliac femoral artery, popliteal artery and inferior genicular artery).The device is indicated to dilate the stenotic vascular to the calculated diameter for the treatment of obstructive disease of peripheral arteries.



Clinical application


Guide wire fitting system 

Site of Lesion 

0.035 system

Iliac artery, superficial femoral artery, proximal popliteal artery, iliofemoral artery, hemodialysis and venous dilation 

0.018 system

Carotid arteries, renal arteries, superficial femoral arteries, infra-knee arteries, stubborn in-stent restenosis 

0.014 system

Inferior knee artery, dorsal foot artery 


Clinical application (Lower extremity) 


PTA Balloon Catheters

Product Features of 0.014" RX PTA Balloon Catheter


  • Angioplasty Balloon Catheter with Rated bursting pressure

--  It can be applied to the expansion of highly calcified lesions

  • Low compliance balloon

-- The new balloon formation method reduces the occurrence of "dog bone" phenomenon

  • The reduced thickness of the balloon wall makes it compatible with the 5Fr sheath


PTA Balloon catheter Technical Specification


Compliance

Balloon

Size

Balloon Length

Shaft

length

Catheter Design

Guidewire Compatility Inch

SC  PTA Balloon

1.5mm- 5.0mm

20- 210mmm

100/130/150cm

coaxial

0.014

SC  PTA Balloon

2.0-9.0mm

20-220mm

90/130/180cm

coaxial

0.018

SC  PTA Balloon

2.0-9.0mm

20-220mm

90/130/180cm

doulbe lumen

0.018

SC  PTA Balloon

2.0-10.0mm

20-220mm

80/130cm

coaxial

0.035

SC  PTA Balloon

2.0-10.0mm

20-220mm

80/130cm

doulbe lumen

0.035

NC  PTA Balloon

2.0-5.0mm

20-220mm

100/150cm

coaxial

0.014

NC  PTA Balloon

2.0-7.0mm

20-220mm

90/130/180cm

coaxial

0.018

NC  PTA Balloon

2.0-7.0mm

20-220mm

90/130/180cm

doulbe lumen

0.018

NC  PTA Balloon

2.0-10.0mm

20-220mm

40/80/130cm

coaxial

0.035

NC  PTA Balloon

2.0-10.0mm

20-220mm

40/80/130cm

doulbe lumen

0.035

More AVF PTA Balloon angioplasty ordering information please contact your sales.


Barty medical Enterprise Operation Principle


Barty Medical shares your commitment to achieving the best possible patient outcomes,

and connecting healthcare professionals with the finest medical technologies and supplies in the market.

Our products range from the consult room to the operating theatre delivering leading technology

into the most capable hands.

By continuing, you are acknowledging that you are a registered healthcare professional with

a valid certification.

We design solutions that support life-saving procedures and satisfy unique application and performance needs, while maintaining tight, repeatable outcomes.

Scoring balloon catheter

 Contact Way


Name: Eiffel Lu

Email: lllu@batymedical.com

Mobile: +86 182 2165 9426(whatsapp)

Hot Tags: 0.014" rx pta balloon catheter, China, suppliers, manufacturers, factory, customized, OEM

Send Inquiry

whatsapp

skype

E-mail

Inquiry

Bag