Chocolate PTA Balloon Catheter With CE Mark

Chocolate PTA Balloon Catheter With CE Mark

Name:Monty TM Chocolate PTA balloon
Material:nitinol-caged balloon
Size: 2.5mm-6.0mm
Recommend Guide: 0.014'' 0.018''
Certificate: CE MARK

Chat Now
Product Introduction

OVERVIEW of Chocolate PTA Balloon Catheter With CE Mark

The Monty TM Chocolate PTA balloon

which the only nitinol-caged balloon with Controlled Dilatation, was designed for 1:1 vessel sizing to minimize flow-limiting dissections and reduce recoil.

As the balloon inflates, the cage causes the balloon to form a series of segmented pillows and grooves along the entire lesion. The pillows apply force to create small dissections that are necessary for effective dilatation. The grooves relieve the stress and stop dissections from propagating.

Chocolate PTA Balloon Catheter With CE Mark INDICATIONS

The Monty TM Chocolate PTA balloon Catheter is intended for balloon dilatation of lesions in the peripheral vasculature, including the iliac, femoral, ilio-femoral, popliteal, infra-popliteal, and renal arteries.

 

PRODUCT DETAILS

The Chocolate PTA balloon is a semi-compliant balloon that is encased in a nitinol-constraining structure, or cage, that allows for 1:1 vessel sizing.

The cage and the balloon expand simultaneously, so as the balloon unwraps, the cage prevents the balloon from catching on lesions and causing torsional stress and dissections.

During inflation, the cage causes the balloon to dilatate in a controlled manner, alleviating dog-boning and over inflation. The cage also causes the balloon to form a series of segmented pillows and grooves along the entire lesion. The pillows apply force to create small dissections that are necessary for effective dilatation. The grooves relieve the stress and stop dissections from propagating.

Design of Chocolate PTA Balloon Catheter

Braided catheter

Improved pushability, excellent anti-kink performance

Hydrophilic coating reduces frictional force on the catheter shaft

Coaxial tip:

Smaller outer diameter for better passing

Semi-compliant balloon

Helps to match the metal mesh with the best concave and convex structure

Constraint structure of Nitinol metal mesh:

Avoid shearing force on blood vessels during balloon expansion

Realize the uniform distribution to prevent the "dog bone" effect

The balloon has excellent reclamation properties, avoiding the "Pancake" effect

Grooves: relieve pressure and optimize plaque

Protrusion: Controllable expansion of blood vessels, minimizing damage caused by blood vessel expansion

 



Hot Tags: chocolate pta balloon catheter with ce mark, China, suppliers, manufacturers, factory, customized, OEM